E17
Hewalex Water Temperature Differential Too High / Flow Imbalance

Hewalex pool heater shows E17; unit may run but with limited performance or stops intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Water flow too low through heat exchanger, Incorrect bypass valve setting, Fouled heat exchanger, Faulty water temperature sensors causing false delta‑T

How to Fix / Troubleshooting

Safety first: Turn off heater and pump before adjusting valves or opening filters.

  • Check flow rate: Ensure the pool pump is correctly sized and running at the required speed. Clean filters and baskets.
  • Adjust bypass: If a bypass is installed, gradually close the bypass to increase flow through the heater, monitoring inlet and outlet pressures.
  • Inspect heat exchanger: Look for signs of scaling or fouling (reduced performance, high delta‑T). Chemical cleaning may be required following Hewalex guidelines.
  • Verify sensors: Check inlet and outlet NTC sensors for correct installation and operation (see E05/E06).
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Titanium Heat Exchanger
Check Price on Amazon

We may earn a commission from links on this page.