F5
Jacuzzi Air Pressure Switch / Combustion Air Proving Fault

Jacuzzi pool heater display shows F5 and the unit will not fire; blower may run briefly then stop.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked exhaust vent or intake, Faulty air pressure switch, Cracked or disconnected pressure tubing, Failed combustion blower

How to Fix / Troubleshooting

Safety first: Turn off power and gas. Do not operate the heater with a suspected vent blockage; risk of carbon monoxide.

Steps to address F5:

  • Inspect vent and intake: Check the flue outlet and combustion air intake (if separate) for leaves, nests, snow, or debris. Clear any obstructions. Ensure vent terminations meet Jacuzzi clearance requirements.
  • Check blower operation: Restore power and call for heat. Listen for the combustion blower. If it does not start, the blower motor or its capacitor may be failed and require replacement.
  • Inspect pressure switch tubing: With power off, locate the air pressure switch and its rubber or silicone tubing. Ensure tubing is not cracked, kinked, or filled with water/condensate. Replace or clear tubing as needed.
  • Test the air pressure switch: Using a multimeter, verify that the switch closes when the blower runs. If it remains open despite proper airflow, replace the switch with a Jacuzzi-compatible air pressure switch.

If F5 persists after clearing vents and verifying the switch and blower, contact a qualified technician to evaluate the combustion system and venting.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Jacuzzi Air Pressure Switch
Check Price on Amazon