FA
Jacuzzi Control Board Communication Fault

Jacuzzi pool heater display shows FA; heater may lock out until power is cycled.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose control board connectors, Corroded harness plugs, Faulty display/keypad board, Failed main control board

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before opening the control panel.

Steps to troubleshoot FA:

  • Inspect wiring harnesses: Remove the front panel and locate the low-voltage harnesses between the main control board and the display/keypad. Unplug and re-seat each connector to wipe oxidation from the pins.
  • Check for moisture: Look for signs of water intrusion or condensation inside the control compartment. Dry the area thoroughly and correct any leaks or missing grommets.
  • Visual board inspection: Examine both boards for burnt components, corrosion, or cracked solder joints.
  • Replace suspect board: If connections are clean and secure but FA persists, replace the display/keypad board first. If the fault remains, the main control board may need replacement.

Board replacement should be done with power off and using anti-static precautions. If unsure, contact a Jacuzzi service technician.