Jacuzzi
Control Voltage Drop / Electrical Interference
Jacuzzi pool heater display and controls reset intermittently, especially when the blower or pump starts.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose neutral or ground connection, Undersized electrical supply, Failing transformer, Electrical noise from pump or blower motor
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before tightening any electrical connections.
Steps to stabilize power:
- Inspect supply wiring: Verify that the heater is on a dedicated circuit sized per Jacuzzi’s requirements. Tighten all lugs at the breaker and heater terminal block.
- Check neutral and ground: Ensure neutral and ground connections are secure and corrosion-free.
- Test transformer output: Measure low-voltage output under load. Replace the transformer if voltage drops significantly when the blower starts.
- Separate circuits: If the pump and heater share a circuit, consider moving them to separate breakers to reduce voltage sag.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Jacuzzi Low-Voltage Transformer
Check Price on Amazon