Jacuzzi
Temperature Overshoot / Control Calibration Issue
Jacuzzi pool heater runs but water temperature overshoots the setpoint by several degrees.
Advertisements
Possible Causes
Slow or mislocated temperature sensor, Oversized heater with small water volume, External controller hysteresis too wide, Sensor not in main water stream
How to Fix / Troubleshooting
Safety first: Turn off power before moving sensors.
Steps to reduce overshoot:
- Verify sensor location: Ensure the Jacuzzi temperature sensor is installed in the main return line, not in a dead leg or bypass.
- Compare temperatures: Use a separate thermometer to confirm actual water temperature vs display. Replace the sensor if readings are inaccurate.
- Adjust controller settings: If using automation, reduce the temperature differential or hysteresis so the heater shuts off closer to setpoint.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Jacuzzi Water Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements