AO2
Jandy Air Flow Fault – Pressure Switch Closed/Open at Wrong Time

Heater shows AO2 and will not fire; blower may run continuously or not at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck air pressure switch, Miswired pressure switch, Faulty blower relay on control board, Blocked vent system

How to Fix / Troubleshooting

Safety first: Disconnect power. Do not bypass safety switches for normal operation.

  • Inspect pressure switch wiring: Verify the air pressure switch wires are on the correct terminals per the wiring diagram inside the heater panel.
  • Check switch operation: With power off, remove the tubing and gently blow through it to ensure it is clear. If the switch appears stuck (continuity when it should be open), replace it.
  • Check venting: Inspect intake and exhaust for obstructions or improper installation that could affect blower operation.
  • If AO2 remains: The control board blower relay or logic may be faulty. Have a technician test the board and replace if necessary.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Air Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.