AO6
Jandy Advanced Air Flow Diagnostic Fault

Display shows AO6; heater fails to complete startup sequence.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect venting configuration, Severe vent restriction, Blower speed feedback error, Control board firmware issue

How to Fix / Troubleshooting

Safety first: Turn off power and do not operate the heater with suspected venting issues.

  • Verify venting: Compare the installed vent size, length, and number of elbows to Jandy installation specifications. Correct any undersized or overly long vent runs.
  • Check terminations: Ensure vent terminations are installed per manufacturer guidelines and are not blocked.
  • Inspect blower feedback wiring: Some models use a feedback signal from the blower; verify the harness is intact and properly connected.
  • If AO6 persists: A technician should evaluate blower performance and update or replace the control board if required.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Control Board
Check Price on Amazon

We may earn a commission from links on this page.