LO
Jandy Low Water Flow / Pressure Switch Open

Display shows LO; heater will not fire or shuts down shortly after starting.

Advertisements

Possible Causes

Insufficient water flow through heater, Dirty pool filter, Closed or partially closed valves, Faulty water pressure switch

How to Fix / Troubleshooting

Safety first: Turn off heater power before working on plumbing. Do not run heater without proper water flow.

  • Verify pump operation: Ensure the pool pump is running at the correct speed and is fully primed.
  • Check valves: Confirm that inlet and outlet valves to the heater are fully open and that bypass valves are correctly positioned.
  • Clean filter: Backwash or clean the pool filter to restore proper flow. A dirty filter is a common cause of LO.
  • Inspect pressure switch: Locate the water pressure switch on the header. Check for leaks, corrosion, or loose wires. If adjustable, verify it is set per Jandy specifications.
  • If LO persists with good flow: The pressure switch may be faulty and should be replaced with a Jandy-compatible water pressure switch.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements