SF
Jandy Safety Fault Lockout

Heater display shows SF and will not run; blower does not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open high limit switch, Tripped manual reset limit, Faulty pressure switch, Loose safety circuit wiring

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker. Do not bypass safety switches.

  • Check water flow: Ensure the pool pump is running and valves are open. Low flow can open the pressure switch and trigger SF.
  • Inspect high limits: Locate the high limit switches on the heat exchanger header. Some models have manual reset buttons; press gently to reset if tripped. If they trip repeatedly, there may be a flow or scaling issue.
  • Check pressure switch: Verify the pressure switch tubing is not kinked or clogged. Inspect the switch wiring and terminals for corrosion.
  • Wiring inspection: Follow the safety circuit wiring (pressure switch, high limits, fusible link) and ensure all connections are tight and not burned.
  • If SF persists: The safety circuit or control board may be faulty. Have a technician test continuity of each safety device and replace the failed component.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

High Limit Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements