E10
Kripsol
Internal Control Board Communication Error
Heater will not start and displays E10 immediately after power-up.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty Kripsol main control PCB, Loose low-voltage harness between display and main board, Power surge damage, Incorrect wiring polarity
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before opening the control compartment. Electronic components are sensitive to static and incorrect wiring.
- Inspect wiring: Remove the front panel and visually inspect all harnesses between the Kripsol display module and main control board. Reseat multi-pin connectors firmly.
- Check supply voltage: Verify that the heater is wired for the correct voltage (e.g., 230 V single-phase) and that line and neutral are not reversed. Use a multimeter if you are qualified.
- Look for board damage: Examine the Kripsol control PCB for burn marks, swollen capacitors, or corrosion. Any visible damage usually requires board replacement.
- Power cycle: After reseating connectors, restore power and see if the error clears. If E10 persists, the control board is likely defective.
- Board replacement: Replacing the Kripsol main control PCB should be done by a qualified technician to ensure correct configuration and safe operation.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Kripsol main control PCB