E17
Kripsol Thermostat Calibration / Sensor Mismatch Fault

Heater shows E17 and stops heating; water temperature may overshoot or undershoot setpoint.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Mismatched Kripsol NTC sensors (inlet vs outlet), Incorrect sensor type installed, Control board firmware not configured for installed sensors, Sensor wiring swapped

How to Fix / Troubleshooting

Safety first: Turn off power before changing sensors or wiring.

  • Verify sensor types: Check part numbers on the Kripsol inlet and outlet NTC sensors and confirm they match the heater’s parts list.
  • Check wiring order: Ensure the inlet sensor is connected to the inlet terminals and the outlet sensor to the outlet terminals on the control board. Swap if they were reversed.
  • Compare readings: With the heater off and water well mixed, inlet and outlet sensors should read nearly the same temperature. If one is significantly different, replace that sensor.
  • Firmware/config: Some Kripsol models allow configuration of sensor type in the installer menu. Verify settings match the installed hardware.
  • Board replacement: If all hardware is correct and E17 persists, the control board may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Kripsol NTC sensor set (inlet and outlet)