Kripsol
External Control Integration Issue
Heater does not respond when external pool automation calls for heat, but works in manual mode.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect wiring between Kripsol heater and automation relay, Wrong control mode selected on heater, Automation set to wrong heater type, Open circuit on remote demand terminals
How to Fix / Troubleshooting
Safety first: Turn off power to both the heater and automation system before working on control wiring.
- Verify mode: On the Kripsol control panel, ensure the heater is set to REMOTE or EXTERNAL mode if controlled by automation.
- Check wiring: Compare the wiring between the automation relay and Kripsol remote terminals to both manuals. Correct any miswiring.
- Test demand signal: With a multimeter, verify that the automation closes the contact or provides the correct signal when heat is requested.
- Bypass test: Temporarily install a jumper across the Kripsol remote terminals to simulate a call for heat. If the heater runs, the issue is in the automation or wiring.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Kripsol remote control terminal block
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements