E09
Lochinvar Thermostat / Control Sensor Error

Display shows E09; heater does not respond to thermostat changes or shows erratic temperature readings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty pool temperature sensor, Damaged control wiring, Defective main control board

How to Fix / Troubleshooting

Safety: Turn off power before removing the control panel.

Steps:

  • Verify setpoint: Confirm the desired pool temperature is set correctly and that the heater is in Pool mode (not Spa, if separate).
  • Check external controls: If using an external pool automation system, ensure the control wiring to the Lochinvar heater is correct and that the external controller is calling for heat.
  • Inspect pool temperature sensor: Locate the remote pool sensor (if equipped) in the plumbing line. Check for secure mounting and intact wiring. Replace if corroded or physically damaged.
  • Test sensor resistance: Disconnect the sensor and measure resistance; compare to Lochinvar's chart. Replace if out of range.

If the sensor tests good but E09 persists, the main control board may need replacement by a qualified technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pool Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.