E11
Lochinvar Air Pressure Switch Open / Inducer Proving Failure

Display shows E11; heater will not fire and indicates air pressure or proving switch fault.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked intake or exhaust, Failed air pressure switch, Cracked or disconnected pressure tubing, Weak blower

How to Fix / Troubleshooting

Safety: Turn off power before accessing internal components.

Steps:

  • Check vent and intake: Ensure both intake and exhaust pipes (if applicable) are clear of obstructions and properly terminated.
  • Inspect pressure tubing: Locate the air pressure switch and its silicone tubing to the blower housing. Check for cracks, kinks, water accumulation, or disconnections. Replace tubing if brittle or damaged.
  • Verify switch operation: With power off, remove the tubing and gently blow through it to ensure it is clear. Do not blow into the switch itself. Confirm the switch mounting and wiring are secure.
  • Test with meter (advanced): A technician can check continuity across the pressure switch with the blower running to confirm operation.

If E11 persists after clearing venting and tubing issues, the pressure switch or blower may need replacement by a qualified technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Air Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements