E13
Lochinvar Ignition Control Module Fault

Display shows E13; heater may lock out and indicate ignition control or flame safeguard error.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective ignition control board, Corrupted control firmware, Internal relay failure, Voltage spikes damaging electronics

How to Fix / Troubleshooting

Safety: Turn off power before touching the control board or wiring.

Steps:

  • Power cycle: Turn off the breaker for 30 seconds, then restore power to see if the error clears.
  • Inspect control board: Remove the control panel cover and visually inspect the ignition control board for burn marks, swollen components, or corrosion.
  • Check connectors: Reseat all multi-pin connectors to the board, ensuring they are fully engaged and keyed correctly.
  • Verify proper grounding: Ensure the heater chassis is properly grounded; loose grounds can cause erratic control behavior.

If E13 returns after basic checks, the ignition control module likely needs replacement. This should be done by a technician to ensure correct configuration and safe operation.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Ignition Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements