Heater displays E08 and refuses to start; may be accompanied by no fan or pump signal.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker and verify no voltage is present before opening the control compartment.
Step-by-step checks:
- Inspect control compartment: Remove the front panel and inspect the Pahlen control board area for signs of water intrusion, condensation, or insect nests. Dry any moisture with a clean cloth and allow the area to air dry completely.
- Check all connectors: Gently press on all multi-pin connectors and terminal blocks on the control board to ensure they are fully seated. Look for burnt or discolored components.
- Power cycle: After ensuring everything is dry and connected, restore power and perform a full power cycle (off for at least 2–3 minutes, then on). See if the error clears.
- Surge protection: If the error appeared after a storm or power event, consider adding an external surge protector to the heater's supply once repairs are complete.
When to stop: If E08 persists, the control board is likely defective and must be replaced or reprogrammed by an authorized Pahlen service provider.
Repair Difficulty
Required Part
We may earn a commission from links on this page.