E05
Pentair
Rollout Switch / Flame Rollout Fault
Heater shows E05 and will not start a heating cycle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped flame rollout switch, Blocked or restricted flue/exhaust, Sooted or blocked burners, Cracked heat exchanger causing abnormal flame pattern
How to Fix / Troubleshooting
Critical safety warning: A rollout fault indicates a potential combustion hazard. Turn off power and gas immediately. Do not continue to operate the heater until the cause is found.
- Inspect rollout switches: Locate the rollout switches near the burner compartment. Check for manual reset buttons; if present, press to reset once only after the unit has cooled. If they trip again, stop and call a professional.
- Check for visible obstructions: Look for debris, nests, or soot buildup in the burner area and exhaust outlet. Do not operate the heater with any visible blockage.
- Examine burners (visual only): If burners appear heavily rusted, warped, or sooted, they may be causing improper flame. Burner removal and cleaning should be done by a qualified technician.
- Professional inspection: Because rollout can indicate a cracked heat exchanger or serious venting problem, have a licensed pool heater technician inspect the combustion chamber, heat exchanger, and venting system before returning the heater to service.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Flame Rollout Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements