E26
Pentair Blower Proving / Air Pressure Switch Stuck

Heater shows E26 and will not fire.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Air pressure switch stuck closed or open, Blocked pressure tubing, Faulty air pressure switch, Blower not achieving proper speed

How to Fix / Troubleshooting

Safety: Turn off power and gas before servicing.

  • Inspect pressure tubing: Locate the small rubber or silicone tube from the blower housing to the air pressure switch. Check for cracks, kinks, or water in the tube. Clear or replace as needed.
  • Test switch operation: With power off, disconnect the wires and check continuity. The switch should be open with blower off and close when blower runs. Replace if stuck or not switching correctly.
  • Check blower performance: Ensure the blower starts promptly and runs smoothly. A weak blower may not create enough pressure to close the switch.
  • Replace air pressure switch: If tubing and blower are good but E26 persists, replace the air pressure switch with the correct Pentair part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Air Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements