E3
Poolex Defrost Protection / Defrost Sensor Error

Poolex pool heater shows E3 and stops; may occur during defrost cycles.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective evaporator/defrost sensor, Sensor not properly attached to coil, Control board defrost algorithm fault, Excessive ice buildup on evaporator

How to Fix / Troubleshooting

Safety: Turn off power before touching internal components. Beware of sharp coil fins.

Steps:

  • Inspect evaporator coil: Check for heavy ice buildup. If present, allow the unit to thaw naturally by turning it off for several hours.
  • Check sensor placement: Ensure the defrost sensor is firmly attached to the coil where originally installed.
  • Clean coil: Remove debris that may be blocking airflow and causing excessive icing.

Sensor replacement:

  • Replace the Poolex defrost/evaporator NTC sensor if it is damaged or reading incorrectly.

If E3 persists, a technician should verify defrost control parameters and main PCB operation.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Defrost Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.