Poolex Insufficient Heating Capacity / Performance Loss

Poolex pool heater runs but pool water does not reach set temperature or heats very slowly.

Advertisements

Possible Causes

Dirty evaporator coil reducing heat absorption, Low refrigerant charge, Undersized Poolex model for pool volume, Low water flow through titanium heat exchanger

How to Fix / Troubleshooting

Safety: Turn off power before cleaning coils or opening panels.

Steps:

  • Verify sizing and expectations: Compare your pool volume and desired temperature rise with the Poolex model's rated kW output. In cold weather, heating will be slower.
  • Clean air coil: Gently wash the evaporator coil with low-pressure water and a soft brush to remove dust and debris.
  • Optimize water flow: Ensure valves are correctly set and filters are clean so the Poolex titanium heat exchanger receives adequate flow.
  • Check operating hours: Run the heater continuously for 24–48 hours during initial heat-up; heat pumps are slow but efficient.

If performance remains poor, a technician should check refrigerant charge and system pressures.