ROL1
Raypak Primary Rollout Switch Open

Display shows 'ROL1' and heater locks out; indicates first rollout circuit open.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Localized flame rollout near primary burner area, Tripped or failed primary rollout switch, Blocked burner orifice near switch location, Improper combustion air supply

How to Fix / Troubleshooting

Safety first: Rollout conditions are dangerous. Turn off gas and power immediately. Allow the heater to cool fully.

Steps to address ROL1 error:

  • Locate primary rollout switch: Find the rollout switch labeled or wired as the primary circuit. Check if it has a manual reset button and reset if tripped.
  • Inspect burner area: Remove burner tray access and look for signs of flame impingement, discoloration, or melted components near the switch.
  • Clean burners: Remove and clean affected burners and orifices. Clear spider webs, rust, or debris that may be redirecting flame.
  • Check combustion air: Ensure the heater has adequate clearance and is not installed in a confined space without proper ventilation.
  • Replace switch if defective: If the switch will not reset or tests open at room temperature, replace it with the correct Raypak rollout switch.

Warning: Do not operate the heater until the cause of rollout is fully corrected.