Possible Causes
Loose temperature sensor connection, Sensor cable run near high-voltage lines, Failing thermistor, Air pockets at sensor location
How to Fix / Troubleshooting
Safety First: Turn off power before handling sensors or wiring.
- Inspect sensor wiring: Check that the inlet, outlet, pool, and spa sensors are firmly connected and that cables are not damaged.
- Reroute cables: If sensor wires run alongside high-voltage conductors, reroute them to minimize electrical interference.
- Bleed air: Ensure there is no trapped air where sensors are installed; air can cause rapid temperature swings.
- Replace faulty sensor: If one sensor consistently reads incorrectly compared to a reference thermometer, replace it with a Rheem-approved sensor.