Possible Causes

Loose temperature sensor connection, Sensor cable run near high-voltage lines, Failing thermistor, Air pockets at sensor location

How to Fix / Troubleshooting

Safety First: Turn off power before handling sensors or wiring.

  • Inspect sensor wiring: Check that the inlet, outlet, pool, and spa sensors are firmly connected and that cables are not damaged.
  • Reroute cables: If sensor wires run alongside high-voltage conductors, reroute them to minimize electrical interference.
  • Bleed air: Ensure there is no trapped air where sensors are installed; air can cause rapid temperature swings.
  • Replace faulty sensor: If one sensor consistently reads incorrectly compared to a reference thermometer, replace it with a Rheem-approved sensor.