E02
SPRSUN Low Pressure Protection / Low Refrigerant

Pool heat pump stops heating and displays E02; fan may run but compressor shuts down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge due to leak, Restricted refrigerant flow in expansion valve, Dirty evaporator coil reducing heat absorption, Faulty low pressure switch

How to Fix / Troubleshooting

Safety first: Switch off power at the breaker and unit disconnect before inspection. Do not attempt to connect gauges or add refrigerant unless you are licensed.

  • Check airflow through evaporator coil: Ensure the top fan is running and there is no obstruction above the unit. Remove leaves, covers, or snow around the air inlet and outlet.
  • Clean coil surface: With power off, remove large debris from the coil fins and gently rinse with a garden hose. Allow to dry before restarting.
  • Verify water flow: Confirm that the circulation pump is running and that the SPRSUN heater has adequate flow (no closed valves, clean filter). Poor heat transfer can cause low suction pressure.
  • Restart and monitor: Restore power and clear the E02 alarm. If the code reappears within minutes, the system may be low on refrigerant or have a restriction.
  • Call a technician: A professional should check the low pressure switch, inspect for refrigerant leaks, and verify the electronic expansion valve (EEV) or capillary system operation.