E05
SPRSUN
Water Outlet Temperature Sensor Fault
Unit displays E05 and stops; water temperature reading is erratic or clearly incorrect.
Advertisements
Possible Causes
Failed water outlet temperature sensor, Loose or corroded sensor connector, Sensor not properly inserted into water pipe well, Faulty main control PCB input
How to Fix / Troubleshooting
Safety first: Turn off power and close isolation valves if you will open any plumbing connections.
- Locate outlet sensor: Find the water outlet temperature sensor on the SPRSUN heater (usually inserted into a sensor well on the outlet pipe).
- Check seating: Ensure the sensor probe is fully inserted into the well and secured with its clip or clamp.
- Inspect connector: Trace the sensor cable to the control board and verify the plug is firmly connected and free of corrosion or moisture.
- Dry and reseat: If moisture is present, dry the connector, apply a small amount of dielectric grease if available, and reconnect.
- Test operation: Restore power and see if the temperature reading is stable and E05 clears. If not, replace the outlet temperature sensor with the correct SPRSUN part.