E07
SPRSUN Fan Motor Fault / Fan Feedback Error

Unit shows E07 and stops; fan may not run or runs briefly then stops.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed fan motor, Obstructed fan blade, Faulty fan capacitor (on non-ECM models), Damaged fan motor wiring or connector

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker. Do not attempt to spin the fan with power on.

  • Check for obstructions: Look through the top grille and around the fan blade for sticks, leaves, or ice blocking movement. Remove any debris.
  • Spin test: With power off, gently try to rotate the fan blade by hand. It should turn freely. If it is stiff or seized, the motor bearings may have failed.
  • Inspect wiring: Remove the top cover (if accessible) and check the fan motor wiring harness and plug for loose connections or burn marks.
  • Capacitor check: On models with a separate fan capacitor, inspect for bulging or leaking. A failed capacitor can prevent the fan from starting.
  • Restart: Restore power and clear the E07 code. If the fan still does not start or E07 returns, replace the fan motor assembly (and capacitor if used).
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fan Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements