E15
SPRSUN Discharge Temperature Protection

Unit shows E15 and stops; may be associated with abnormal compressor noise or vibration.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser airflow, Overcharged refrigerant, Non-condensable gases in system, Faulty discharge temperature sensor

How to Fix / Troubleshooting

Safety first: Disconnect power before inspection. Do not attempt to adjust refrigerant charge yourself.

  • Check airflow: Ensure nothing is blocking the top discharge or side inlets. Maintain recommended clearances around the SPRSUN heater.
  • Clean condenser coil: Gently rinse the coil fins with a garden hose to remove dirt and debris.
  • Verify fan operation: Confirm that the fan starts and runs at normal speed when the unit operates.
  • Inspect sensor: Locate the discharge temperature sensor on the compressor discharge line. Make sure it is firmly attached and the wiring is intact.
  • Call a technician: If E15 persists, a professional should check discharge temperature, system pressures, and refrigerant charge, and replace the sensor if faulty.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Discharge Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements