SPRSUN Fan Failure without Error Code

Fan does not spin but compressor appears to run; unit becomes very hot on top.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed fan motor, Faulty fan capacitor, Obstruction preventing fan rotation, Loose fan motor wiring

How to Fix / Troubleshooting

Safety first: Immediately turn off power if the compressor runs without the fan; this can damage the system.

  • Check for obstructions: With power off, inspect the fan area for debris or ice blocking movement. Remove any obstruction.
  • Spin test: Try to rotate the fan blade by hand. If it is stiff or seized, the motor likely needs replacement.
  • Inspect capacitor: On models with a separate fan capacitor, look for bulging or leaking. Replace with the same microfarad rating and voltage.
  • Verify wiring: Ensure the fan motor connector is fully seated on the control board or terminal block.
  • Replace motor: If the fan still does not start, replace the fan motor assembly with a SPRSUN-compatible part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fan Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements