E10
Sta-Rite
External Control / Thermostat Input Error
Heater shows E10 and will not fire; often associated with external automation systems
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect wiring from pool automation, Shorted remote thermostat terminals, Faulty external control board
How to Fix / Troubleshooting
Safety: Turn off power before working on low-voltage wiring. Do not short thermostat terminals intentionally.
- Check mode of operation: Confirm whether the Sta-Rite heater is set to local control or remote/automation mode per the user interface.
- Inspect remote wiring: Open the low-voltage wiring compartment and verify that the remote thermostat or automation wires are correctly landed on the designated Sta-Rite terminals.
- Test without automation: Temporarily disconnect the external control wires and configure the heater for standalone operation. If E10 clears and the heater runs, the issue is with the automation system or wiring.
- Check for shorts: Use a multimeter to check for shorts between thermostat wires and ground. Repair or replace damaged cable.
- Consult automation manual: Ensure the external controller is configured for the correct heater model and communication protocol.
Advertisements
Repair Difficulty
Medium
3/5