E19
SunHeater Mode Valve / Sensor Configuration Error

Heater displays E19; occurs when switching between pool and spa modes

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect pool/spa sensor placement, Miswired mode valve actuators, Control board configuration error, Faulty mode sensor

How to Fix / Troubleshooting

Safety: Turn off power before working on valve actuators or sensors.

  • Verify sensor locations: Ensure the Pool Temperature Sensor is installed in the pool return line and the Spa Temperature Sensor in the spa return line, as per SunHeater instructions.
  • Check actuator wiring: Confirm that pool/spa valve actuators are wired to the correct terminals on the automation system or SunHeater control.
  • Test sensors individually: Disconnect each sensor and measure resistance. Compare to the temperature/resistance chart. Replace any sensor that is open, shorted, or out of range.
  • Reconfigure control: Enter the installer menu (see manual) and verify that the system is set for the correct number of bodies of water (pool only vs pool+spa) and that sensors are assigned correctly.
  • Test mode switching: After corrections, switch between pool and spa modes and confirm that valves move correctly and temperatures read accurately.