Possible Causes

Pump speed below heater minimum flow, Sensitive pressure switch setting, Partially clogged filter, Undersized plumbing

How to Fix / Troubleshooting

Safety: Adjust pump speeds from the pump controller; no need to open the heater for basic checks.

  • Check minimum flow: Refer to the SunHeater manual for the minimum required flow rate or pressure. Program the pump to run at or above this speed when heating.
  • Clean filter: Backwash or clean the pool filter to reduce system resistance.
  • Adjust pressure switch (if adjustable): Some Water Pressure Switches have an adjustment screw. Slightly lower the trip point so the heater stays on at lower flows, but never bypass the switch.
  • Test different speeds: Find the lowest pump speed at which the heater runs reliably and use that as the heating speed.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements