F07
Thermeau
Inlet Water Temperature Sensor Fault
Heater shows F07 and shuts down; may occur during operation as water warms.
Advertisements
Possible Causes
Failed Thermeau inlet temperature sensor, Loose or corroded sensor connector, Shorted or open sensor wiring, Sensor not properly seated in well
How to Fix / Troubleshooting
Safety first: Disconnect power before opening the control panel or touching sensors.
- Locate inlet sensor: The inlet sensor is usually mounted on or near the heater’s inlet header. Refer to the Thermeau wiring diagram for identification.
- Inspect sensor and harness: Check for physical damage to the sensor body or cable. Ensure the harness is not pinched by panels or rubbing against sharp edges.
- Verify connection at board: Remove and reinsert the sensor connector on the control board to ensure a solid electrical connection.
- Check sensor seating: If the sensor sits in a thermowell, confirm it is fully inserted and making good thermal contact.
- Replace if necessary: If F07 persists and the displayed inlet temperature is erratic or unrealistic, replace the inlet thermistor with the correct Thermeau part.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Thermeau Inlet Temperature Sensor
Check Price on Amazon