F18
Thermeau Ambient Temperature Sensor Fault / Freeze Sensor Error

Heater shows F18 and will not run; may be associated with freeze protection or low ambient temperatures.

Advertisements

Possible Causes

Failed Thermeau ambient/freeze sensor, Sensor wiring open or shorted, Sensor not properly located in airflow, Control board input fault

How to Fix / Troubleshooting

Safety first: Disconnect power before working on sensors or wiring.

  • Locate ambient sensor: On some Thermeau models, a separate sensor monitors outdoor or cabinet temperature for freeze protection. Identify its location from the service manual.
  • Inspect sensor and cable: Check for physical damage, rodent chewing, or disconnection.
  • Check reading: Compare the displayed ambient temperature (if available) to actual outdoor temperature. A large discrepancy indicates a bad sensor.
  • Replace sensor: Install a new Thermeau ambient/freeze sensor if readings are incorrect or F18 persists.
  • Board check: If a known-good sensor does not clear F18, the control board input may be defective and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Thermeau Ambient / Freeze Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements