Thermeau
External Control / Automation Not Starting Heater
Heater display is on but unit does not respond to a call for heat from the pool automation system.
Advertisements
Possible Causes
Incorrect wiring between automation and Thermeau fireman’s switch terminals, Automation not configured for heater control, Open contact in external thermostat, Broken low-voltage control cable
How to Fix / Troubleshooting
Safety first: Turn off power before changing any low-voltage wiring.
- Switch to local control: Put the Thermeau heater into local/manual mode (if available) and set a temperature above current water temp. If the heater starts, the issue is with external control.
- Check automation settings: Verify that the pool controller is configured to enable the heater and that the desired body (pool/spa) is active.
- Inspect control wiring: At the heater, confirm that the external control wires are connected to the correct Thermeau terminals and that the cable is intact.
- Test contact closure: With a multimeter, verify that the automation provides a proper dry contact closure when heat is requested.
- Correct wiring or replace cable: Fix any miswiring and replace damaged control cable as needed.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Thermeau Fireman’s Switch Terminal Block
Check Price on Amazon
We may earn a commission from links on this page.