Thermeau Post-Purge Fan Overrun

Heater fan continues to run for an unusually long time after burners shut off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Control board post-purge timer stuck, Flue temperature sensor reading high, Relay on Thermeau board welded closed, Wiring short keeping fan energized

How to Fix / Troubleshooting

Safety first: Turn off power before accessing the control board or fan wiring.

  • Understand normal behavior: Some post-purge fan run is normal to cool the heat exchanger. Compare duration to Thermeau specifications.
  • Check flue temperature: If the flue sensor reads high after shutdown, the board may keep the fan on. Investigate causes of high flue temperature such as scale or vent blockage.
  • Inspect board relays: Look for signs of overheating or damage on the fan relay. A stuck relay can keep the fan running.
  • Wiring check: Ensure the fan is wired only through the control board and not accidentally tied to constant power.
  • Replace board if needed: If the relay is welded or logic is faulty, replace the Thermeau control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Thermeau Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements