Thermeau
No Power / Dead Unit
Heater will not start at all; display is completely blank and unlit.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped breaker or blown fuse feeding Thermeau heater, Loose power connection at terminal block, Internal fuse on control board blown, Failed main control board power supply
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before opening the electrical compartment. Only qualified persons should test live circuits.
- Check breaker: Verify the circuit breaker for the heater is not tripped. Reset if necessary and observe if it trips again.
- Inspect power wiring: Remove the electrical access cover on the Thermeau heater and confirm that line wires are securely attached and not burned.
- Test incoming voltage: With a multimeter, confirm correct voltage at the heater’s input terminals.
- Check internal fuse: Locate any internal fuse on the control board or power entry. Replace only with the same type and rating if blown.
- Board replacement: If power is present at the board but the display remains dead, the control board’s power supply is likely failed and the board should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Thermeau Main Control Board
Check Price on Amazon