E04
Zodiac High Limit Switch Trip / Overheat Condition

Zodiac pool heater shows E04 and shuts down; often occurs shortly after startup.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Restricted water flow, Scale buildup in heat exchanger, Faulty high limit switch, Bypass valve misadjusted

How to Fix / Troubleshooting

Safety: Turn off power and allow the heater to cool before touching internal components.

  • Check water flow: Ensure the pump is running at the correct speed (for variable-speed pumps) and that filters and baskets are clean. Low flow can cause rapid temperature rise and trip the high limit.
  • Inspect bypass and valves: Verify that any internal or external bypass is set according to Zodiac specifications. Too much bypass can reduce flow through the heat exchanger.
  • Examine high limit switches: Locate the high limit switches on the header/manifold. Check for loose connections or signs of overheating. With power off, test continuity with a multimeter; a tripped or failed switch will be open.
  • Descale heat exchanger (advanced): If the heater is older or used with hard water, internal scaling may be restricting flow. This typically requires a professional to chemically descale or replace the heat exchanger.
  • Replace faulty high limit: If flow is correct and the switch tests open at normal temperatures, replace the high limit switch with a Zodiac-approved part.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

High Limit Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements