E16
Zodiac Low Line Voltage / Power Supply Fault

Zodiac pool heater shows E16; may be associated with low-voltage or power issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Undersized wiring, Loose power connections, Low supply voltage from panel, Failing transformer

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before opening the electrical junction box. Only work on line voltage if you are qualified.

  • Inspect power connections: Verify that all line and neutral connections at the heater's terminal block are tight and free of corrosion or heat damage.
  • Check wire size and length: Compare installed wire gauge and run length to Zodiac installation requirements. Undersized wire can cause voltage drop.
  • Measure voltage: With power on and using a multimeter, measure line voltage at the heater while the unit is attempting to run. Voltage should be within the specified range (typically ±10% of nominal).
  • Check transformer output: If equipped with a low-voltage transformer, measure its secondary output. A weak or failed transformer can cause control issues.
  • Correct supply issues: Tighten connections, replace damaged wiring, or have an electrician correct panel or supply problems. Replace the transformer with a Zodiac-compatible unit if defective.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Power Transformer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements