Zodiac Repeated Ignition Lockout / Safety Lockout

Zodiac pool heater repeatedly locks out and must be manually reset to restart.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Intermittent flame sensing, Marginal gas supply, Faulty ignition control board, Unstable power supply

How to Fix / Troubleshooting

Safety: Frequent lockouts indicate an unresolved fault. Do not repeatedly reset without diagnosing the cause.

  • Record conditions: Note when lockouts occur (windy, cold, after long off periods) to help identify patterns.
  • Inspect and clean ignition components: Clean the igniter and flame sensor, check wiring, and ensure proper burner flame as described in other entries.
  • Check gas and power stability: Have a professional verify gas pressure and electrical supply stability.
  • Replace ignition control board: If all mechanical and supply issues are resolved and lockouts persist, the ignition control module may be faulty and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Ignition Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements