AO Smith Internal Thermal Protector Cycling

AO Smith pool pump motor cycles on and off repeatedly during operation without tripping the breaker.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overheating due to blocked ventilation, High ambient temperature, Overloaded pump curve, Failing thermal protector inside motor

How to Fix / Troubleshooting

Safety First: Disconnect power before inspection.

  • Improve cooling: Clear debris from motor vents and ensure adequate airflow around the AO Smith motor.
  • Check load: Verify that the pump is not dead-headed and that filter pressure is within normal range.
  • Measure current: Have a technician measure running amps. If near or above nameplate rating, reduce system head or consider a lower HP motor.
  • Replace motor if protector is weak: If cycling occurs even at normal load and temperature, the internal thermal protector may be failing and the motor should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Motor Assembly
Check Price on Amazon