AO Smith Incorrect Rotation

AO Smith pool pump motor runs in the wrong direction (for reversible models or after wiring changes).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Miswired reversible motor leads, Incorrect connection of line and neutral on certain models, Wrong replacement motor type installed

How to Fix / Troubleshooting

Safety First: Turn OFF power before changing any wiring.

  • Confirm rotation: Observe water flow and motor fan direction. Most AO Smith pool motors are single-direction; if flow is poor and fan appears reversed, suspect wiring.
  • Check wiring diagram: Compare current connections to the AO Smith nameplate diagram. Correct any swapped leads for reversible models.
  • Verify motor type: Ensure the replacement motor matches the original pump’s rotation requirement (CW or CCW).
  • Test after correction: Restore power and verify proper flow and quiet operation.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements