AO Smith No Display / Dead Control Panel

AO Smith variable-speed pool pump display is blank, but line voltage is present at the motor.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown low-voltage fuse on control board, Failed display module, Faulty control transformer or power supply on board, Loose internal connectors

How to Fix / Troubleshooting

Safety Warning: Internal components may carry hazardous voltages. Only qualified persons should service the control board.

  • Verify line power: Confirm that correct voltage is present at the pump’s line terminals.
  • Inspect internal fuses: With power OFF, open the control housing and look for small fuses on the AO Smith control board. Replace only with identical type and rating if blown.
  • Check connectors: Ensure the display ribbon cable and other harnesses are fully seated.
  • Look for board damage: Inspect for burned components or corrosion. If present, the board should be replaced.
  • Replace display or board: If fuses and wiring are good but the display remains blank, replace the display module or entire control board/drive module as specified by AO Smith.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Control Board / Drive Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements