E17
AquaFlo Auxiliary Sensor / Heater Interlock Fault

E17 displayed; pump cannot detect water temperature or heater interlock status (on integrated systems).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected water temperature sensor, Broken heater interlock wiring, Failed AquaFlo auxiliary input circuit, Incorrect jumper configuration

How to Fix / Troubleshooting

Safety first: Turn off power to the pump and any connected heater before servicing auxiliary wiring.

  • Check sensor connection: Locate the water temperature sensor or heater interlock terminals on the AquaFlo control board. Ensure connectors are fully seated.
  • Inspect cable: Follow the sensor or interlock cable to the heater or plumbing. Look for cuts, abrasions, or rodent damage. Replace if damaged.
  • Measure sensor resistance: Disconnect the sensor and measure its resistance with a multimeter. Compare to AquaFlo’s temperature vs. resistance chart. Replace if out of range.
  • Verify jumpers: If no heater is installed, ensure the appropriate jumper is installed across the interlock terminals as specified in the manual.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

AquaFlo Water Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.