AquaFlo Stuck Relay / Control Logic Fault

Pump will not turn off from the keypad; continues running until breaker is switched off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Welded motor relay contacts on AquaFlo control board, Shorted control output transistor, Keypad failure sending constant run command, External automation overriding local control

How to Fix / Troubleshooting

Safety first: Use the breaker to shut off power before opening the control housing.

  • Disconnect external control: Temporarily disconnect any automation or remote start wires and test if local OFF command works.
  • Inspect relay: Open the controller and locate the motor relay. Look for signs of overheating or melted plastic.
  • Test keypad: Observe if other buttons respond normally. If only the OFF function fails, the keypad may be defective.
  • Replace control board or relay: If the relay contacts are welded closed, replace the AquaFlo control board or have the relay replaced by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

AquaFlo Digital Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements