Aquaflow
Failed Control Panel or Low-Voltage Power Supply
Pump display is blank but power is present at the terminals
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown low-voltage fuse on control board, Failed internal power supply, Damaged display module
How to Fix / Troubleshooting
Safety first: Turn off power and wait for capacitors to discharge before opening the control housing.
- Check internal fuse: Locate any low-voltage fuses on the Aquaflow control board and test/inspect them. Replace only with identical type and rating.
- Measure low-voltage output: If equipped, check for 5V/12V outputs from the board to the display using a multimeter.
- Inspect display cable: Ensure the display ribbon cable is firmly connected.
If low-voltage power is missing or the display remains blank, the control board or display module must be replaced.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Aquaflow control board assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements