Aquaflow Failed Control Panel or Low-Voltage Power Supply

Pump display is blank but power is present at the terminals

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown low-voltage fuse on control board, Failed internal power supply, Damaged display module

How to Fix / Troubleshooting

Safety first: Turn off power and wait for capacitors to discharge before opening the control housing.

  • Check internal fuse: Locate any low-voltage fuses on the Aquaflow control board and test/inspect them. Replace only with identical type and rating.
  • Measure low-voltage output: If equipped, check for 5V/12V outputs from the board to the display using a multimeter.
  • Inspect display cable: Ensure the display ribbon cable is firmly connected.

If low-voltage power is missing or the display remains blank, the control board or display module must be replaced.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Aquaflow control board assembly