Aquaflow
Suction-Side Air Leak
Pump runs but there are large amounts of air bubbles in the pool returns
Advertisements
Possible Causes
Loose pump lid, Cracked suction fittings, Worn union O-rings, Air leak at vacuum hose connection
How to Fix / Troubleshooting
Safety first: Turn off the pump before tightening fittings.
- Check lid seal: Ensure the Aquaflow pump lid O-ring is clean, lubricated, and the lid is tight.
- Inspect unions: Tighten suction-side unions and replace O-rings if flattened or cracked.
- Vacuum hose test: Remove any vacuum hoses and run the pump on skimmer/main drain only to see if bubbles disappear.
- Soap test: With the pump running, apply soapy water to suspected joints; bubbles being sucked in indicate leaks.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Aquaflow suction union O-rings
Check Price on Amazon
We may earn a commission from links on this page.