Aquaflow
Electrical Short Circuit
Pump trips the circuit breaker immediately when turned on
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted motor windings, Water inside motor junction box, Damaged power cord or conduit, Shorted control board components
How to Fix / Troubleshooting
Safety first: Do not repeatedly reset a tripping breaker. Turn off the breaker and leave it off until the fault is found.
- Inspect wiring: Check the Aquaflow pump's power cable, junction box, and conduit for visible damage or burn marks.
- Check for moisture: Open the motor terminal box and control housing to look for water or corrosion. Dry thoroughly if present.
- Isolate motor: Disconnect the motor leads from the control board or terminal block. Turn on the breaker with the motor disconnected. If it still trips, the wiring or control board is suspect; if not, the motor is likely shorted.
Shorted motors or boards should be replaced by a qualified technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Aquaflow pump motor assembly
Check Price on Amazon
We may earn a commission from links on this page.