E20
AquaJet
Start Circuit / Relay Fault
Display shows E20 and pump will not start; internal relay clicks once.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed internal start relay on control board, Burned relay contacts, Loose motor lead connection
How to Fix / Troubleshooting
Safety first: Disconnect power and verify zero voltage before opening the control housing.
- Inspect motor leads: Ensure all motor leads are securely fastened to the AquaJet control board output terminals.
- Listen for relay: With the cover on and power restored, attempt to start the pump and listen for a click. A click with no motor response often indicates burned contacts.
- Check for discoloration: With power off, inspect the control board around the relay for heat damage.
- Replace control board: The start relay is typically not field‑serviceable; replace the AquaJet control board assembly if E20 persists.