Possible Causes
Tripped breaker at pool sub‑panel, Faulty GFCI outlet or breaker, Loose or disconnected supply wiring at AquaJet terminal block
How to Fix / Troubleshooting
Safety first: Use caution when working in electrical panels. Turn off the main breaker if necessary and verify circuits are de‑energized.
- Check breakers and switches: Verify that the pool pump breaker and any external disconnects are in the ON position and not tripped. Reset if necessary.
- Test GFCI: If the pump is fed from a GFCI, press RESET. If it will not reset, there may be a ground fault or failed GFCI that needs replacement.
- Verify voltage at pump: With a multimeter and appropriate safety precautions, measure voltage at the AquaJet power terminals. If no voltage is present, trace back through junction boxes to find the open connection.
- Inspect terminal block: With power off, tighten all terminal screws and look for burned or loose wires. Repair or replace damaged components.