ERR4
AstralPool Internal Drive / Inverter Fault

Pump display shows ERR4 and will not start; sometimes appears after a power surge or lightning storm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed power board components, Damage from power surge, Loose internal harness between keypad and main PCB

How to Fix / Troubleshooting

Safety first: Isolate power at the breaker and wait at least 5 minutes for internal capacitors to discharge before opening any covers.

  • Power cycle the unit: Turn off the breaker for 2–3 minutes, then restore power and attempt to start the pump. Transient faults may clear.
  • Inspect external wiring: Check that line, neutral and earth are correctly connected and tight at the pump terminal block. Incorrect wiring can trigger drive faults.
  • Check for surge damage: Look for burn marks or a burnt smell around the control housing. If present, do not attempt further operation.
  • Reset controller (if menu allows): Some AstralPool controllers have a factory reset option in the settings menu. Perform a reset following the user manual, then reprogram schedules.

ERR4 usually indicates an internal electronics failure. Replacement of the power/control PCB or complete drive module is typically required and should be done by an authorized AstralPool service agent.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Drive / Inverter PCB Assembly
Check Price on Amazon