E10
Bestway Keypad / User Interface Failure

Pump display shows E10 and the unit will not respond to button presses.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged membrane keypad, Moisture under control panel overlay, Loose ribbon cable between keypad and PCB, Failed user interface circuit on PCB

How to Fix / Troubleshooting

Safety first: Disconnect power before opening any control covers.

  • Dry the panel: If the keypad has been exposed to rain or splashes, gently dry the surface and edges with a soft cloth. Do not use solvents. Allow the panel to air dry in a shaded, dry area.
  • Check for stuck buttons: Press each button individually several times to free any that may be stuck. Look for physical damage or tears in the keypad overlay.
  • Inspect internal connection (if accessible): Remove the control panel cover and verify that the keypad ribbon cable is fully inserted into the PCB connector. Reseat it carefully.
  • Test operation: Restore power and check if the display responds. If E10 remains and buttons are unresponsive, the keypad or PCB may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Bestway pump control keypad
Check Price on Amazon

We may earn a commission from links on this page.